Technical specifications of sealed acid unicor 12v-70ah battery

  • Product type: battery
  • Battery Type: Sealed Acid (VRLA)
  • Number of cells: 6
  • Voltage: 12 V
  • Capacity: 70 amp hours
  • Internal resistance: 6 milliohms
  • Maximum charging rate: 19.5 amps
  • Dimensions: 260*167*209 mm
  • Weight: 23.5 kg

About UNIKOR battery supplier company

Unikor sealed acid UPS battery is a product from South Korea. This battery brand is one of the batteries with a long life. The UNIKOR Korean battery will last about 10 to 12 years at a temperature of 20 degrees Celsius, and this figure will vary according to the operating temperature of the battery. To buy Unicor 70 amp battery online, stay with us in the next article.

UNICOR UPS 70 amp battery

Unicor Sealed Acid Battery was established in South Korea in 1995 with the aim of producing long life batteries. EV series is a maintenance-free type VRLA battery for electric vehicles. Excellent high current discharge performance is one of its obvious advantages . This series is well suited for highly uncertain power applications that require batteries to provide additional cyclic performance such as outdoor applications, small RE systems, and electric vehicles.

Battery Specifications High shield acid unicor

What features does Unicore 70 amp battery have?

-Pb-Ca-Sn multicomponent alloy, high purity electrolytic lead

– Lead paste with high density and special long effective additive

– Excellent cycle life and overdischarge recovery performance

– high thick mesh, low calcium Sn with special paste

– Advanced AGM separator for high pressure cell design

– wide operating temperature range

Unicore 70 amp battery is used in what cases?

  • elevator
  • telecommunications equipment
  • Electric garage door
  • home consumption
  • Emergency power systems
  • hospital and medical equipment
  • UPS UPS
  • oil, gas and petrochemical industry
  • Emergency lighting systems
  • Computer networks and data centers and server rooms
  • Solar power systems
  • Data centers and server rooms
  • Portable audio and video systems
  • safety and security systems
  • Electric wheelchair
  • Wheelchairs
  • Forklift
  • Solar and solar systems

How to maintain Unicor 70 amp UPS battery:

UPS batteries are sealed acid and do not require maintenance, but there are some things that must be observed in order to increase the life of the battery. For this purpose, the following must be observed:

 How to maintain UPS battery

1- Proper charging and discharging:

One of the most important issues for UPS batteries is charging and discharging according to the standard tables of each type of battery. If this is done correctly, it will significantly increase the useful life of the batteries. UPS charger devices with new technology should be used. Also, it is better to periodically check the voltage of the batteries, the amount of voltage and the charger and the charging current by an expert to determine that the process of charging and discharging the battery cycle is done correctly.

2– suitable temperature:

Another factor of battery failure is the heat and high temperature of the environment or factors that cause the battery to heat up, such as improper charging and discharging with high amperage. The ambient temperature of the battery must be between 20 and 30 degrees Celsius according to the standard listed in the catalog.

3- Connections and main batteries:

Another important issue that should be considered is the periodic inspection and visit of batteries. In every visit, make sure that the connections between the batteries are completely tight, the battery terminals (terminals) are not oxidized, and the battery is not too hot or swollen. In case of oxidation, first remove the batteries from the circuit and then completely clean the batteries with boiling water and sandpaper so that the conductivity of the batteries is completely maintained. Avoid contact of sulfates with clothing and skin when cleaning battery heads. Because sulfates are acidic and harm your skin and clothes. It is worth mentioning that by observing the above-mentioned issues, the useful life of the batteries increases and the entire capacity of the batteries can be used optimally.

4– the same voltage of the batteries:

Considering that UPS batteries are connected in series and all batteries receive the same amount of charging current; In each periodic service, the voltage of each battery should be measured separately to determine that all batteries have the same quality. If it is determined that one or more batteries have a lower voltage than other batteries, these batteries must be removed from the circuit. In devices that work with high direct voltage (DC), if one or more batteries are damaged, these batteries receive the same amount of current as healthy batteries. This causes damaged batteries to overheat, and if this process continues, it can eventually lead to a fire. Therefore, voltage control is very important in every service.

5- Battery cabinet:

In order to avoid short circuit and possible impact, as well as to have a stylish appearance, you must use suitable battery cabinets. These cabinets are made in different sizes and dimensions, according to the number and capacity of batteries, and they usually have rust-resistant static colors and are made of suitable alloy with standard thickness. To choose a battery, we need to use a suitable battery cabinet for order and safe storage of batteries. Click on the link to get enough information about battery rack and cabinet.

fia2

Buying guide from Tesla

Tesla company, a supplier of all kinds of UPS batteries with the lowest price in the market, serves all customers. If you have any questions and requests for advice about your purchase, you can contact the support numbers and share your problem and question with our experts. You can also buy these products from Cactus Store.

Support and communication numbers with Tesla (02188312456 / 02188861253)

Nominal voltage

12 volts

Capacity

70 amps

Manufacturing Country

South Korea

the length

260 mm

width

167 mm

Height

209 mm

life span

10 years

Weight

23.5 kg

Suitable for

  • elevator
  • telecommunications equipment
  • Electric garage door
  • home consumption
  • Emergency power systems
  • hospital and medical equipment
  • UPS UPS
  • Electric bicycle
  • Wheelchair
  • and ….

Advantages and Disadvantages

-Pb-Ca-Sn multicomponent alloy, high purity electrolytic lead

– Lead paste with high density and special long effective additive

– Excellent cycle life and overdischarge recovery performance

– high thick mesh, low calcium Sn with special paste

– Advanced AGM separator for high pressure cell design

– wide operating temperature range

– Long lifespan

Battery catalog

Unicor 4.5 amp battery catalog