UPS for film photometer

Back1
+

as you know UPS is an uninterrupted power supply. This electronic tool supplies the electric current needed by the consumer’s electric devices during a power cut, and in this regard, after re-establishing the municipal electric current, it is responsible for regulating and maintaining the electricity grid; In addition, this device prevents the penetration of noise and disturbances in sensitive consumer equipment.

Among the influencing factors during UPS powering, the following can be mentioned:

The number of systems and the amount of load connected to the UPS

The capacity of the battery used in the input UPS

UPS working method

Among the duties of UPS and how UPS works, the following can be mentioned:

Adjusting and modifying or increasing and reducing the output and input voltages, with the aim of providing an acceptable voltage for the device.

Providing electricity needed by consumer equipment with desirable quality and continuously

All this happens when the regional electricity supplier has general or partial problems.

Types of UPS

The types of these electronic tools are:

Offline UPS

On line UPS

UPS Interactive or Line Interactive UPS

This type of UPS is activated in the circuit during a power cut.

Online UPS or On line UPS

The task of this type of UPS is to transfer the correct output to the load by correcting the input voltage or stabilizing the input from noise. Therefore, the output is usually provided by these types of UPS.

UPS for film photometer device

Also read: How many hours does the UPS work?

Interactive UPS or Line Interactive UPS

The task of this type of UPS is to provide AC output without input disturbances, and this means, in normal times, to transfer the input to the transformer through the bypass mode. In this case, the transformer will actually control the charger.

UPS components

Battery (Battery): with the purpose of storing electrical energy and using it as a source of electrical energy in ups

Inverter (Inverter): In order to convert direct current into alternating current

Charger (Charger): with the purpose of charging the UPS battery and converting alternating current to direct current

Rectifier (Rectifier): In order to convert the incoming alternating current into direct current

In addition, the efficiency of these UPSs is significantly less compared to other types of UPS and their internal consumption, depending on their types, is between five to It is ten times more than other models.

UPS has many applications in various fields. One of the common fields of application of UPS is laboratory equipment, the most important of which is the film photometer.

Getting to know the film photometer device

In order to calculate the concentration of sodium, lithium and potassium in the blood and the concentration of sodium and potassium. A device named flame photometer has been designed and produced and entered the market. This device uses lithium as an internal reference so that in addition to increasing accuracy, it is also possible to compensate for the internal changes of the device itself. This device is used for timely measurement of lithium concentration in blood, potassium as an internal reference.

Read also: UPS suitable for bacteriological culture incubator devices

Implementing steps settings and calibrating the device before starting work:

1- Flawless connection of the device to the electrical system
2- Correctly connecting the device to the gas system and adjusting the amount of gas to light the flame
3- In order to provide compressed air, the compressor must be properly connected.
4- Turning on the film itself
5- Turn on the compressor system for the purpose of entering compressed air into the device
6- Open the gas system
7- When gas reaches the candle, in order to form a flame, it is necessary to press the female professional chassis to cause a flame and then that the flame is stable and It is stable, we will start to adjust it. The flame that lights up must have a light blue color and be in the shape of a sugar cube.
8- After stabilizing the flame, by changing the selector key of three positions of lithium, sodium and potassium, place the key on one of the three relevant factors and the desired standard of the device We present it to the device through the needle (atomizer needle) and the color of the flame changes.

9- In the next step, the detector which is located behind the optical filter of the device; It senses the value of the passing current and gives it to the circuit of the device and is processed by the processor and after the circuit analysis, the final answer is displayed on the LCDdisplay. /strong> device is displayed. Now, if the standard value displayed on the screen is the standard value engraved on the glass of the standard material; be the same This means that the device has no technical defects and is calibrated. After that, we are allowed to give the patient sample to the machine and according to the doctor’s order, check the related factor and get the final answer from the machine and send it to the treatment system. do

From Tesla

If you intend to buy electrical and electronic equipment for medical and hospital centers , Medical EquipmentHomes, Departments and Organizations, Elevators and LiftsATMselectric shutter, water and gas coolers, computer systems Telecom Systems, Data Centers,Dental Equipment, Safety Equipment, Labs, Lighting Equipment and … you have, you can contact us. Our colleagues and educated experts are willing to give any advice and answer your questions, dear buyers.