Reasons for shutting down the UPS

back2
+

UPS is an uninterrupted power supply. This electronic tool supplies the electricity needed by the consumer’s electrical appliances during a power cut, and in this regard, after installation The re-flow of urban electricity is responsible for regulating and maintaining the electricity of the grid; In addition, this device prevents the penetration of noise and disturbances in all devices. Stay with us to know the reasons for the UPS shutdown

The shutdown of the UPS can have many reasons, some of which we will explain. One of the reasons and at the same time the most important one is the wearing of the UPS circuit, which can be the result of continuous work for several years.

One of the problems that occur with UPS is its sudden shutdown, when the UPS shuts down, the devices connected to it also shut down. When the UPS is turned off, the first thought that comes to one’s mind is the failure of the UPS, but no, it is not like this, and there is no need to replace it as soon as possible. Think about repairing it. You can easily fix problems and obstacles that prevent the UPS from turning on

Not keeping the UPS battery empty for a long time

It is very important that the UPS, especially its battery, should not be left unused in the warehouse, and sometimes the battery should be used and charged. do it

Read also: UPS suitable for laboratory

If you have not used the UPS for a long time, it will cause the UPS to wear out and fail, which will cause the UPS to turn off in order to prevent the battery from wearing out. PS, charge the device once every three months for five hours. This is the nature of UPS batteries.

Reasons for UPS shutdown

Activation of unnecessary devices

If you do not connect the connections and devices to the UPS correctly, the UPS will turn on those devices that do not need to be turned on and stay on, and the necessary devices that need to be turned on. It turns off the intensity you have for them. To solve this problem connect the essential devices directly to the UPS and connect other devices to the additional media or If it increases the capacity of the UPS , you can not connect it.

UPS shutdown when disconnected from the main source:

If your UPS suffers from this problem, in the first step, check the existing capacity of the UPS and connect the devices to the UPS according to the capacity.

Also read: Guide to choosing a professional UPS for your needs</a a

It is also possible that there is no capacity to support a large number of devices due to the exhaustion of the UPS battery. To solve this problem, disconnect unnecessary devices from the UPS and turn it on again.

UPS battery failure

The useful life of the UPS battery is different from the use of the user. There are special devices that test the UPS battery and show the output voltage of the battery. If it has been two years or more since you bought and used your UPS, it is better to replace the battery, but be sure to test it before replacing it. .

From Tesla

If you intend to buy electrical and electronic equipment for medical and hospital centers , Medical EquipmentHomes, Departments and Organizations, Elevators and LiftsATMselectric shutter, water and gas coolers, computer systems Telecom Systems, Data Centers,Dental Equipment, Safety Equipment, Labs, Lighting Equipment and … you have, you can contact us. Our colleagues and educated experts are willing to give any advice and answer your questions, dear buyers.