Battery UPS 12V 7A YUASA NP7-12

Technical specifications of UPS battery yuasa np7-12

  • Brand: yuasa
  • Type of UPS: Sealed Acid
  • Dimensions: 151*65*97.5 mm
  • Nominal voltage: 12V

  • Ampere: 7A
  • Approximate weight: 2.2 Kg

Buying Yuasa 7 amp battery

Yusa Battery UPS was established in Japan in 1979 with the provision of motorcycle batteries. But with the passage of time, carefully following the demands of the market, it has emerged in the field of creating UPS batteries and has overtaken its competitors. In 2002, this collection succeeded in obtaining the global UPS standard. Now, by creating more uses of battery, it has the ability to make about 43% of transactionsBattery South Korea in your hands. YUASA battery manufacturing plant has spread all over the world and is used in most UPSs. Buy a 7 amp UPS battery in the following article

Technical specifications of the 7 amp Yuasa NP7-12 battery

This sealed acid battery uses the power of 12 volts and the capacity of 7 amp hours. The dimensions of the battery are 151 x 65 x 97.5 mm and the weight is 2.2 kg. The operating temperature range for battery charging is between -15 to +50 degrees Celsius, and the operating temperature range for battery discharge is between -20 and +60 degrees Celsius. The material of the battery body is made of durable ABS and protects against battery electrolyte leakage. YUASA one of the world’s largest battery manufacturers and a global leader in quality and innovation in It is a battery. The battery giant has 65 subsidiaries and 36 affiliates worldwide. YUASA is the global leader in two-wheeler batteries and the first ranking in Asia for car batteries. Since its establishment, GS Yuasa Group has continuously contributed to economic development and improvement of living standards through the development and manufacture of batteries. /a>, Power Supply Systems and Lighting Equipment helped.

How to maintain Yuasa 7 amp battery

UPS batteries are sealed acid and do not require maintenance, but there are some things that must be observed in order to increase the life of the battery. For this purpose, the following must be observed:

How to maintain UPS battery

1- Proper charging and discharging:

One of the most important issues for UPS batteries is charging and discharging according to the standard tables of each type of battery, which if done correctly will significantly increase the useful life of the batteries. UPS chargers with new technology should be used. It is better to periodically check the battery voltage by an expert to ensure that the battery is fully charged and measure the voltage, charger and charging current so that the charging and discharging cycle of the battery is done correctly.

2– suitable temperature:

Another factor of battery failure is the high temperature of the environment or factors that cause the battery to heat up, such as improper charging and discharging with high amperage. The ambient temperature of the battery must be between 20 and 30 degrees Celsius according to the standard listed in the catalog.

3- Connections and main batteries:

Another important issue that should be considered is the periodic inspection and visit of batteries. In each visit, make sure that the connections between the batteries are completely tight, the battery terminals (terminals) are not oxidized, and the battery is not too hot or swollen. In case of oxidation, first remove the batteries from the circuit and then completely clean the batteries with boiling water and sandpaper so that the conductivity of the batteries is completely maintained. When cleaning the battery head, avoid contact of sulfates with clothes and skin because sulfates are acidic and will harm your skin and clothes. It is worth mentioning that by observing the above-mentioned issues, the useful life of the batteries has increased and the entire capacity of the batteries can be used optimally.

4– the same voltage of the batteries:

UPS batteries are connected in series and all batteries receive the same charging current. In each periodic service, the voltage of each battery should be measured separately to determine that all batteries have the same quality. If one or more batteries have a lower voltage than the other batteries, these batteries must be removed from the circuit. In devices that work with high direct voltage (DC), if one or more batteries are damaged, these batteries receive as much current as healthy batteries. This causes damaged batteries to get very hot, and if this process continues, it can eventually lead to a fire, so voltage control is very important in every service.

5- Battery cabinet:

In order to avoid short circuit and possible impact, as well as to have a stylish appearance, you must use suitable battery cabinets. These cabinets are made in different sizes and dimensions, according to the number and capacity of batteries, and they usually have rust-resistant static colors and are made of suitable alloy with standard thickness.

Buying guide from Tesla

Tesla company, the supplier of all kinds of UPS batteries with the lowest price in the market, serves all customers.

If you have questions and requests for advice, you can contact the support numbers and discuss with the experts.

You can also get Yasa 7 amp battery from Cactus Store.

Support and communication numbers with Tesla (02188312456 / 02188861253)

Manufacturing Country

Japan

Nominal voltage

12 volts

Capacity

7 amps

the length

151 mm

width

65 mm

Height

97.5 mm

life span

3 to 5 years

Weight

2.2 kg