Technical specifications of the 12v 26ah rocket battery:

  • Product type: battery
  • Battery Type: Sealed Acid (VRLA)
  • Voltage: 12 V
  • Capacity: 26 amp hours
  • Internal resistance: 12 milliohms
  • Dimensions: 165*176*127 mm
  • Weight: 8.1 kg

rocket UPS battery (ROCKET)

SEBANG Global Battery Company is the most famous battery manufacturing company in South Korea which started the production of power supply and battery equipment under the brand Rocket in May 1952. Recently, this company, adhering to the preservation of the environment, seeks to expand the production technology and increase the lifespan of its batteries and supply the highest quality product. From the very beginning, the products of this collection had the highest possible level among similar products in terms of quality and international standards. Specifications of the 26-amp rocket battery in the next article

26 amp rocket UPS battery

The lead-acid batteries produced in Rocket company are designed and produced in three types of ESH, ES and ESL with the most advanced technology in the world for a wide range of applications. The use of calcium alloy with unique and high purity has resulted in a long lifespan for rocket batteries that work well in different conditions. These types of batteries are specially designed for high charging and discharging times and are the most suitable option for continuous power outages. The special mold and the use of sealing epoxy completely prevents electrolyte leakage and makes the battery maintenance-free.

Shield acid battery with rechargeable capability

Good recharging after long-term discharges is one of the most unique features of these batteries. After the fifth year, the battery capacity decreases in the ESL series compared to the ESH series, for example, in the eighth year with an environment with a temperature of 25 degrees Celsius. The ESH series reaches approximately 65% ​​of its nominal capacity, while the ESL series rocket battery has approximately 80% of its nominal capacity in the same amount of time.

How to maintain the UPS battery

UPS batteries are sealed acid and do not require maintenance, but there are some things that must be observed in order to increase the life of the battery. For this purpose, the following must be observed:

How to maintain UPS battery

1- Proper charging and discharging:

One of the most important issues for UPS batteries is charging and discharging according to the standard tables of each type of battery, which if done correctly will significantly increase the useful life of the batteries. UPS chargers with new technology should be used. It is better to periodically check the battery voltage by an expert to ensure that the battery is fully charged and measure the voltage, charger and charging current so that the charging and discharging cycle of the battery is done correctly.

2– suitable temperature:

Another factor of battery failure is the heat and high temperature of the environment or factors that cause the battery to heat up, such as improper charging and discharging with high amperage. The ambient temperature of the battery must be between 20 and 30 degrees Celsius according to the standard listed in the catalog.

table of specifications and operating temperature of the battery

3- Connections and main batteries:

Another important issue that should be considered is the periodic inspection and visit of batteries. In each visit, make sure that the connections between the batteries are completely tight, the battery terminals (terminals) are not oxidized, and the battery is not too hot or swollen. In case of oxidation, first remove the batteries from the circuit and then completely clean the batteries with boiling water and sandpaper so that the conductivity of the batteries is completely maintained. When cleaning the battery head, avoid contact of sulfates with clothes and skin because sulfates are acidic and will harm your skin and clothes. It is worth mentioning that by observing the above-mentioned issues, the useful life of the batteries has increased and the entire capacity of the batteries can be used optimally.

4– the same voltage of the batteries:

Considering that UPS batteries are connected in series and all batteries receive the same amount of charging current, the voltage of each battery must be measured separately in each periodic service to determine all batteries. They have the same quality. If it is determined that one or more batteries have a lower voltage than other batteries, these batteries must be removed from the circuit. In devices that work with high direct voltage (DC), if one or more batteries are damaged, these batteries receive the same amount of current as healthy batteries. This causes damaged batteries to get very hot, and if this process continues, it can eventually lead to a fire, so voltage control is very important in every service.

5- Battery cabinet:

In order to avoid short circuit and possible impact, as well as to have a stylish appearance, you must use suitable battery cabinets. These cabinets are made in different sizes and dimensions, according to the number and capacity of batteries, and usually have static colors resistant to rust and are made of suitable alloy with standard thickness.

Buying guide from Tesla

Tesla company, the supplier of all kinds of UPS batteries with the lowest price in the market, serves all customers.

If you have questions and requests for advice, you can contact the support numbers and discuss with the experts.

You can also get different types of UPS batteries from Cactus Store.

Support and communication numbers with Tesla (02188312456 / 02188861253)

Manufacturing Country

South Korea

Voltage

12 volts

Capacity

26 amps

the length

165 mm

width

176 mm

Height

127 mm

Weight

8.1 kg

life span

5 to 10 years

Suitable for

  • Fire alarm and extinguishing systems
  • Elevator control circuit board
  • Automatic door control circuit
  • Audio and acoustic systems
  • Medical equipment
  • power supplies and UPS
  • Emergency power systems and UPS
  • emergency support systems
  • Telecom systems
  • Emergency lighting
  • Solar, wind, hybrid power systems and…
  • Types of equipment that require DC power and…

catalog