Battery UPS 12 V 4.5 Amp Optima Optima

Technical specifications of Optima 12v 4.5ah battery:

  • Product type: battery
  • Battery type: Shield acid (VRLA)
  • Voltage: 12 V
  • Capacity: 4.5 amp hours
  • Internal resistance: 30 milliohm
  • Dimensions: 90*7*101 mm
  • Weight: 1.5 kg

Battery 12 V 4.5 amp Optima

4.5 amp Optima battery type lead acid Produced in China. Optima UPS battery sales are extremely high due to its quality and long life. So that 46 countries of the world are applying for this battery. The primary activities of this company are in the field of producing car batteries for car, motorcycle and most vehicle manufacturers. OPTIMA battery (Optima) in Iran in 2001 with the aim of improving the quality level UPS, battery and supplying the needs of commercial, industrial and household community of Iran was established.

Battery sealed acid 12 V 4.5 amp Optima

Optima Group operates in the field of producing all kinds of sealed acid batteries. Sildylacid or Sildacid is a type of acid batteries that, due to their engineering structure, can be used in various fields without the need for repairs. Sealed acid batteries are used for different electrical applications, but their most important application is in places with high power outages and the need for DC power.

Optima manufactures sealed lead acid batteries. Sealed lead acid or sealed acid is a type of lead acid batteries that, due to their engineering structure, can be used in various fields without the need for repairs. Sealed acid batteries are used for different electrical applications, but their most important use is in places with high power outages and the need for DC power.

technical specifications of Optima 4.5 amp battery

How to maintain a 4.5 amp sealed acid batteryOptima

UPS batteries are sealed acid and do not require maintenance, but there are some things that must be observed in order to increase the life of the battery. For this purpose, the following must be observed:

How to maintain UPS battery

1- Proper charging and discharging:

One of the most important issues for the 4.5 amp Optima battery is charging and discharging according to the standard tables of each type of battery. If this is done correctly, the useful life of the batteries will increase significantly. For this reason, UPS charger devices with modern and new technology should be used. It is better to periodically measure the voltage, charger and charging current so that the charging and discharging cycle of the battery can be done correctly.

2– suitable temperature:

Another factor of battery failure is the high temperature of the environment or factors that cause the battery to heat up, such as improper charging and discharging with high amperage. The ambient temperature of the battery must be between 20 and 30 degrees Celsius according to the standard listed in the catalog.

3- Connections and main batteries:

Another important issue that should be considered is the periodic inspection and visit of batteries. In each visit, make sure that the connections between the batteries are completely tight, the battery terminals (terminals) are not oxidized, and the battery is not too hot or swollen. In case of oxidation, first remove the batteries from the circuit and then completely clean the battery heads with boiling water and sandpaper so that the conductive state of the battery heads is completely maintained. When cleaning the battery head, avoid contact of sulfates with clothes and skin surface because sulfates are acidic and will harm your skin and clothes. It is worth mentioning that by observing the above-mentioned issues, the useful life of the batteries increases and the entire capacity of the batteries can be used optimally.

4– the same voltage of the batteries:

Batteries are connected in series and all batteries receive the same charge current. In each periodic service, the voltage of each battery should be measured separately to determine that all batteries have the same quality. If one or more batteries have a lower voltage than other batteries, these batteries must be removed from the circuit. In devices that work with high direct voltage (DC), if one or more batteries are damaged, these batteries receive as much current as healthy batteries. This causes the damaged batteries to heat up, and if this process continues, it can eventually lead to a fire, so voltage control is very important in every service.

5- Battery cabinet:

In order to avoid short circuit and possible impact, as well as to have a stylish appearance, you must use suitable battery cabinets. These cabinets are made in different sizes and dimensions, according to the number and capacity of batteries, and they usually have rust-resistant static colors and are made of suitable alloy with standard thickness. For more information on choosing a battery cabinet, it is recommended to read Battery Rack and Cabinet Read.

Buying guide from Tesla

Tesla company, the supplier of all kinds of UPS batteries with the lowest price in the market, serves all customers.

If you have questions and requests for advice, you can contact the support numbers and discuss with the experts.

You can also get kinds of batteries from Cactus store.

Support and communication numbers with Tesla (02188312456 / 02188861253)

Manufacturing Country

china

Voltage

12 volts

Capacity

4.5 amps

the length

90 mm

width

70 mm

Height

101 mm

Weight

1.5 kg

life span

5 to 10 years

Suitable for

  • Fire alarm and extinguishing systems
  • Elevator control circuit board
  • Automatic door control circuit
  • Audio and acoustic systems
  • Medical equipment
  • power supplies and UPS
  • Emergency power systems and UPS
  • emergency support systems
  • Telecom systems
  • Emergency lighting
  • Solar, wind, hybrid power systems and…
  • Types of equipment that require DC power and…

Advantages and Disadvantages

Great price and battery life
Having high quality compared to other batteries
Stable quality and high reliability
Ability to charge and discharge repeatedly