Product specifications:

  • Battery type: VRLA
  • Battery voltage: 12 V DC type
  • Battery capacity: 150 amp hours
  • Terminal type: M8/18
  • Charging operating temperature range: 0 to 40 degrees Celsius
  • Discharge operating temperature range: -20 to 50 degrees Celsius
  • Dimensions: 338*174*277.5 mm
  • Weight: 44.5 kg
  • No need for maintenance (adding water or electrolyte)
  • Long life (10 to 18 years at 20°C)
  • Safe operation (according to EN 50272 standard)
  • Possibility of installation in different modes (vertical, horizontal)
  • UL approved
  • VDS approved for some specific models
  • High efficiency and reliability
  • Retrievable

Fiam company operates in Italy with a history of at least 80 years in the field of producing and supplying all kinds of batteries. This reputable company has managed to gain more than 4% of the battery sales share in the world by offering all types of sealed acid and gel batteries and power plant batteries as well as the new generation of smart salt batteries with unique capabilities. Fiam 12FLB540 battery specifications in the next article

Fiam UPS battery technical specifications 12FLB540

Fiam UPS Battery 12flb540

Fiam 12FLB540 battery has a capacity of 150 amp hours. This product is a dry battery type VRLA (acid shielded without the need for distilled water or acid) suitable for UPS, control systems, electrical equipment and…

A battery for professional applications with a lifespan of 10-18 years and is sold in the electrical and electronic equipment market. The voltage in this lead acid battery which measures 338*172*277.5 mm is produced with a weight of 44.5 kg, it is 12 V of DC type. The charging operating temperature range of this sealed acid battery is 0 to 40 degrees Celsius and its discharge operating temperature range is -20 to 50 degrees Celsius.

Benefits and salient features of Fiam 12FLB540 battery:

  • Attractiveness of networks with a high degree of purity of lead, calcium-tin alloy cast
  • Active substances on both sides of the networks guarantee performance optimization
  • Minimum network growth and corrosion resistant for long life
  • Electrolyte completely separated in glass mat “AGM”
  • Send leakage resistant seal to prevent acid leakage over a wide temperature range
  • Highest unloading speed or software setting
  • UPS emergency power systems
  • data centers and network and server information technology
  • Emergency lighting
  • 12V lights
  • Very high energy for more compact battery design
  • Very easy installation inside the battery cabinet
  • Protection against excessive discharge
  • anti body
  • Having a design (AGM) and combined exhaust gas release technology
  • No maintenance required
  • No dangerous gases and chemicals harmful to the environment
  • 100% recyclable

How to maintain the UPS battery:

How to maintain UPS battery

UPS batteries are sealed acid and do not require maintenance, but there are some things that must be observed in order to increase the life of the battery. For this purpose, the following must be observed:

1- Proper charging and discharging:

One of the most important issues for batteries is charging and discharging according to the standard tables of any type of battery, which if done correctly will significantly increase the useful life of the batteries.

UPS chargers with new technology should be used. It is better to periodically check the battery voltage by an expert to ensure that the battery is fully charged and measure the voltage, charger and charging current so that the charging and discharging cycle of the battery is done correctly.

2– suitable temperature:

Another factor of battery failure is the high temperature of the environment or factors that cause the battery to heat up, such as improper charging and discharging with high amperage. The ambient temperature of the battery must be between 20 and 30 degrees Celsius according to the standard listed in the catalog.

3- Connections and main batteries:

Another important issue that should be considered is the periodic inspection and visit of batteries. In each visit, make sure that the connections between the batteries are completely tight, the battery terminals (terminals) are not oxidized, and the battery is not too hot or swollen. In case of oxidation, first remove the batteries from the circuit and then completely clean the batteries with boiling water and sandpaper so that the conductivity of the batteries is completely maintained.

When cleaning the battery head, avoid contact of sulfates with clothes and skin because sulfates are acidic and will harm your skin and clothes. It is worth mentioning that by observing the above-mentioned issues, the useful life of the batteries has increased and the entire capacity of the batteries can be used optimally.

4– the same voltage of the batteries:

Considering that UPS batteries are connected in series and all batteries receive the same amount of charging current, the voltage of each battery must be measured separately in each periodic service to determine all batteries. They have the same quality. If it is determined that one or more batteries have a lower voltage than other batteries, these batteries must be removed from the circuit.

In devices that work with high direct voltage (DC), if one or more batteries are damaged, these batteries receive the same amount of current as healthy batteries. This causes damaged batteries to get very hot, and if this process continues, it can eventually lead to a fire, so voltage control is very important in every service.

5- Battery cabinet:

In order to avoid short circuit and possible impact, as well as to have a stylish appearance, you must use suitable battery cabinets. These cabinets are made in different sizes, according to the number and capacity of batteries, and they usually have rust-resistant static colors and are made of suitable alloy with standard thickness.

Buying guide and advice from Tesla

The Tesla company is one of the specialized and reliable organizations that offers the best UPS batteries in different brands, including Fiam. One of the most specialized activities of Tesla company is the repair of different brands of UPS, including Fiam. For advice and guidance on purchasing Tesla products, especially UPS, please contact our experts and consultants through the following communication channels.

To buy Fiam 12FLB540 battery, you can visit Cactus take action.

02188312456

02188861253

You can contact via WhatsApp for online consultation.

09194551896 and 09104609393

Nominal voltage

12 volts

Capacity

150 amps

Manufacturing Country

Italy

the length

338 mm

width

174 mm

Height

5.277 mm

Weight

44.5 kg

life span

10 to 18 years

applications

• Security systems
• Fire extinguishing systems
Uninterruptible power systems (UPS)
• Message transmission systems (signaling)
• Emergency lighting systems
• Media (Broadcast)
• Elevator automation systems